140CPU42402 CPU接口支持模块 可以使用NOM、NOE和MMS模块的任意组合
Modicon控制器模块140 CPU 424 02的量子硬件规格为最大570 K的IEC程序、2 M的SRAM大小和所需的1.8 A总线电流。该单元的可用寄存器是64 k,梯形逻辑也是64 k。
140 CPU 424 02 CPU的前面有部件模块号和描述,这些部件模块号和描述用颜色编码。零件号正下方的区域是LED位置。140 CPU 424 02 CPU有一个可拆卸的门,LED区域下方有一个客户识别标签。在门盖下面,你可以找到连接和电池放置的地方。电池放置在中间部分。电池正下方是两个插槽,用于内存保护和comm参数滑动开关。滑动开关位置下方有三个连接器。一个Modbus连接器、一个用于通道A的Modbus连接器和一个用于通道b的Modbus plus连接器。
- 电话/Phone:15359458915 (微信同号)
- 邮箱/Email:sales@fyplc.cn
- 地址:漳州市龙文区朝阳北路1号办公楼205
★一手货源,没有中间商赚差价!库存1个亿!
★只要是您想要的,我能帮您找到,价格最优!
★厂家原装,保证售后服务,所有产品质保1年!
产品详细说明
产品详情:140CPU42402 CPU接口支持模块
Modicon 140 CPU 424 02is is a CPU interface support module designed for Modicon Quantum Automation systems. It is manufactured by Schneider Electric in an independent configuration. The Modicon controller module 140 CPU 424 02 can support up to 6 optional module interfaces.
feature
The quantum hardware specifications for Modicon controller module 140 CPU 424 02 include a maximum IEC program of 570 K, 2 M SRAM size, and the required 1.8 A bus current. The available registers for this unit are 64 k, and the ladder logic is also 64 k.
The front of the 140 CPU 424 02 CPU has component module numbers and descriptions, which are color coded. The area directly below the part number is the LED position. 140 CPU 424 02 CPU has a detachable door and a customer identification label below the LED area. Under the door cover, you can find a place to connect and place the battery. The battery is placed in the middle section. Below the battery are two slots for memory protection and comm parameter sliding switches. There are three connectors below the sliding switch position. One Modbus connector, one Modbus connector for channel A, and one Modbus plus connector for channel B.
advantage
The Modbus module has one (1) serial port (9-pin D housing), and the Modbus Plus has two (2) redundant network ports (9-pin D housing). Power on diagnosis includes RAM, RAM address, execution checksum, user logic check, and processor. Runtime diagnostics include RAM, RAM address, checksum execution, and user logic checks. The required bus current for Modicon 140 CPU 424 02 is 1.8 A. The power allocation is 9 W, and the TOD clock is+/-8.0 seconds per day at 0… 60 ° C. The maximum number of connections for NOM, NOE, and MMS modules is 6. Any combination of NOM, NOE, and MMS modules can be used.
The LED description is as follows. Green indicates that the CPU has passed power on diagnosis and is ready. When starting and solving logic in running mode, it will remain green. Green also indicates that communication on Modbus and Modbus Plus is active. Amber indicates that the memory is write protected. The red indicator has errors A and B. Error A indicates a communication error with redundant Modbus Plus port A. Error B indicates a communication error between the redundant module and port B.
The 140 CPU 424 02 controller module has a maximum of 64 k in and 64 k out words on the local I/O board. The maximum number of I/O racks is 2 and requires an extender. The maximum I/O for remote I/O is 64 input and 64 output words per path, and the maximum number of remote paths is 31. Distributed I/O can have up to 3 remote branches, which requires the use of the 140NOM2x00 optional module. Distributed I/O has a maximum of 500 input and 500 output words per network.
热销商品:140CPU42402 CPU接口支持模块
| REXA SMB9215-1E-1-7725 | GE IS220PVIBH1A 336A4940CSP16 | Honeywell 05701-A-0361 |
| BENTLY 146031-01 | ABB 5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101 | Honeywell 05704-A-0145 |
| GE HYDRAN M2 | GE IS420UCSCH2A-C-V0.1-A | TRICONEX 4351B |
| HIMA F8650E | KONGSBERG RCU502 | ABB VBX01BA |
| ICS TRIPLEX T8403 | ABB PFEA111-20 3BSE028140R0020 | ABB VBX01TA |
| ICS TRIPLEX T8403 | ABB PFEA111-65/3BSE050090R65 | FOXBORO P0926PA |
| ABB PP846A 3BSE042238R2 | HIMA F3430 | ABB DDC779BE02 3BHE006805R0002 |
| ABB PP846 3BSE042238R1 | PTM PSMU-350-3 | FOXBORO FBM233 P0926GX |
| ABB LDGRB-01 3BSE013177R1 | GE 8102-HO-IP | HP E1406A |
本篇文章出自漳州风云电气设备有限公司官网,转载请附上此链接: http://www.fyplc.cn/